If you buy our CDCP practice engine, you can get rewords more than you can imagine. On the one hand, you can elevate your working skills after finishing learning our CDCP study materials. On the other hand, you will have the chance to pass the exam and obtain the CDCPcertificate, which can aid your daily work and get promotion. All in all, learning never stops! It is up to your decision now. Do not regret for you past and look to the future.

EXIN CDCP Exam Syllabus Topics:

TopicDetails
Topic 1
  • Equipment Racks: It discusses power rail
  • strip options, security considerations, and rack standards, properties and selection criteria.
Topic 2
  • Electro Magnetic Fields: The topic deals with effects of EMF on human health and equipment (H)EMP, standards, and EMF shielding solutions.
Topic 3
  • Water Supply: This topic is all about water supply techniques and application areas.
Topic 4
  • Power Infrastructure: It focuses ATS and STS systems, redundancy levels and techniques, static and dynamic UPS systems, battery types, thermo-graphics, and renewable energy factor (REF).
Topic 5
  • Fire Safety
  • Protection: This topic gives an understanding of standards for fire suppression, detection systems, total flooding fire suppression techniques, and handheld extinguishers. Additionally, it covers Signage and safety.
Topic 6
  • Cooling Infrastructure: The topic focuses on liquid immersion cooling, supplemental cooling options, sensible and latent heat definitions, and temperature and humidity recommendations.
Topic 7
  • Physical Security and Safety: Sub-topics are about physical security considerations and physical safety considerations.
Topic 8
  • Light: This topic covers light fixture types and placement, emergency lighting, and emergency Power Supply (EPS).
Topic 9
  • Raised Floor
  • Suspended Ceiling: The topic discusses applicable standards, signal reference grid, and disability act and regulations.
Topic 10
  • Auxiliary Systems: The topic covers water leak detection systems, data centre monitoring requirements, EMS, BMS and DCIM.
Topic 11
  • Data Centre Location, Building and Construction: It focuses on appropriate sites and components of an effective data centre and supporting facilities setup.

>> CDCP Valid Dumps Ppt <<

EXIN certification CDCP exam best training materials

At SurePassExams, we strive hard to offer a comprehensive Certified Data Centre Professional (CDCP) (CDCP) exam questions preparation material bundle pack. The product available at SurePassExams includes Certified Data Centre Professional (CDCP) (CDCP) real dumps pdf and mock tests (desktop and web-based). Practice exams give an experience of taking the Certified Data Centre Professional (CDCP) (CDCP) actual exam.

EXIN Certified Data Centre Professional (CDCP) Sample Questions (Q25-Q30):

NEW QUESTION # 25
What factor should be considered when placing fluorescent lighting in the data centre?

  • A. Fluorescent lights should only be installed in equipment supporting areas and not in the Computer/Server room.
  • B. Fluorescent lights should not be connected to the mains power supply.
  • C. Fluorescent lights should not be connected to the same UPS that supports the ICT equipment.
  • D. Fluorescent lights should not be connected to the back-up generator.

Answer: C

Explanation:
The UPS (uninterruptible power supply) is a device that provides backup power to the ICT equipment in case of a power outage or a power quality issue. The UPS should be dedicated to the ICT equipment only, and not to other loads, such as lighting, cooling, or security systems. This is because connecting fluorescent lights to the same UPS as the ICT equipment can cause several problems, such as:
*Reducing the battery runtime of the UPS, which may not be enough to support the ICT equipment until the backup generator kicks in or the utility power is restored.
*Increasing the harmonic distortion of the UPS output, which can affect the performance and reliability of the ICT equipment and the UPS itself.
*Creating electromagnetic interference (EMI) or radio frequency interference (RFI), which can disrupt the communication and data transmission of the ICT equipment.
*Triggering false alarms or tripping the circuit breakers of the UPS, which can cause downtime or data loss.
Therefore, fluorescent lights should not be connected to the same UPS that supports the ICT equipment.
Instead, they should be connected to a separate power source, such as the utility power, the backup generator, or a different UPS.
References:
1: CDCP Preparation Guide, page 17, section 2.3.1 2: Data Center Lighting Design Considerations3, page 1, section 3 4: Data Center Lighting Solutions5, page 1, section 1 6: Going beyond energy savings in data centers with LEDs7, page 1, section 2


NEW QUESTION # 26
What is the main difference between an Environmental Monitoring System (EMS) and a Building Management System (BMS)?

  • A. A BMS is only able to monitor dry contacts (on/off). An EMS can also monitor analog values.
  • B. A BMS only operates as a stand-alone system. An EMS can be configured as a redundant system.
  • C. An EMS monitors only. A BMS monitors and controls.
  • D. An EMS provides local alarms. A BMS provides both local and remote alarms.

Answer: C

Explanation:
The main difference between an Environmental Monitoring System (EMS) and a Building Management System (BMS) is that an EMS monitors only, while a BMS monitors and controls. An EMS is a system that collects and records data from various sensors and devices that measure environmental parameters, such as temperature, humidity, air quality, power, and water. An EMS provides alerts and reports based on the data, but it does not control or adjust the environmental conditions. A BMS is a system that integrates and manages various building systems, such as HVAC, lighting, security, fire, and access. A BMS not only monitors the data from these systems, but also controls and optimizes them to achieve the desired performance and efficiency. A BMS can also communicate with an EMS to receive data and provide feedback.
References:
1: Environmental Monitoring Systems vs Building Management Systems2, page 1, section 1 3: Building Monitoring System vs Environmental Monitoring System4, page 1, section 1 5: BUILDING AND ENVIRONMENTAL MANAGEMENT SYSTEMS AND HOW THEY MEET GMP ...6, page 1, section 1 7:
Environmental Monitoring System vs. Building Management System8, page 1, section 1


NEW QUESTION # 27
What is the purpose of a service corridor?

  • A. It provides a secure area where supporting facilities can be serviced and monitored on a 24x7 basis without disturbing the computer room.
  • B. It is a generic name for pathways leading to other rooms that contains facility supporting equipment like the UPS room, battery room, generator room etc.
  • C. To create a secure and conditioned environment where media can be stored in a controlled manner.
  • D. It provides a safe, vented and secure area where standby generators can operate safely.

Answer: A

Explanation:
A service corridor is a dedicated space within or adjacent to a data centre that allows access to the supporting facilities, such as power, cooling, fire suppression, security, and cabling systems, without interfering with the computer room operations. A service corridor helps to isolate the noise, vibration, heat, and dust generated by the supporting facilities from the sensitive equipment in the computer room. A service corridor also enhances the safety and efficiency of the maintenance and monitoring activities, as well as the flexibility and scalability of the data centre design.
References: EPI Data Centre Training Framework, CDCP Preparation Guide, Service Corridors Definition | Law Insider


NEW QUESTION # 28
A fire extinguisher in the data centre is found which is classed as ABC.
Is this suitable?

  • A. Only for fires not related to electrical power
  • B. Depends on the brand
  • C. No
  • D. Yes

Answer: C

Explanation:
A fire extinguisher in the data centre that is classed as ABC is not suitable, because it contains dry chemical powder that can damage the ICT equipment and the data. ABC fire extinguishers are designed to fight Class A, B, and C fires, which are fueled by combustible materials, flammable liquids or gases, and electrical equipment, respectively. However, the dry chemical powder can leave a corrosive residue on the ICT equipment, which can cause short circuits, data loss, or malfunction. Moreover, the dry chemical powder can be difficult to clean, especially from the small spaces and crevices of the ICT equipment. Therefore, ABC fire extinguishers are not recommended for data centres, and should be replaced with more suitable fire extinguishers, such as clean agent fire extinguishers, which use gas or liquid that does not leave any residue or harm the ICT equipment.
References:
1: CDCP Preparation Guide, page 24, section 2.4.3 2: Data Center Fire Suppression: Overview & Protection Guide3, page 1, section 1 4: Fire Extinguisher Classes and Suitability5, page 1, section 1 6: SAFETY DATA SHEET Commercial ABC Dry Chemical (Fire Extinguishing Agent ...7, page 1,


NEW QUESTION # 29
Which type of Fire Detection Device is recommended for protecting a Data Center?

  • A. Smoke detector
  • B. None of the above
  • C. Heat detector
  • D. Flame detector

Answer: A

Explanation:
According to the CDCP® Preparation Guide, smoke detectors are the most common type of fire detection devices used in data centers, as they can detect a fire in its early stages and provide early warning to the occupants and authorities. Smoke detectors can be either spot-type or air-aspirating, depending on the design and goals of the data center. Spot-type detectors are inexpensive and simple, but may cause activation delay and false alarms. Air-aspirating detectors are more sensitive and reliable, but may require more maintenance and installation costs. Both types of detectors should be installed in accordance with the relevant standards and codes, such as NFPA 72 and EN 54.
References: CDCP® Preparation Guide, page 30-31. Evaluating Fire Detection Options For Data Centers. Fire Detection and Suppression Systems in a Data Center.


NEW QUESTION # 30
......

We can provide absolutely high quality guarantee for our CDCP practice materials, for all of our EXIN CDCP learning materials are finalized after being approved by industry experts. Without doubt, you will get what you expect to achieve, no matter your satisfied scores or according CDCPcertification file. As long as you choose our Certified Data Centre Professional (CDCP) exam questions, you will get the most awarded.